iec 61000 4 2 pdf

IEC 61000-4-2:2008 defines typical waveform of the discharge current, range of test levels, test equipment, test setup, test procedure, calibration procedure and measurement uncertainty. IEC 61000-4-2:2008 gives specifications for test performed in "laboratories" and "post-installation tests" performed on equipment in the final installation.

iec 61000 4 2 pdf

IEC 61000-4-6:2013 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150 kHz up to 80 MHz. The standard IEC 61000-4-2 explains in detail the different test setups depending on the EUT (ie table top equipment, floor standing equipment, grounded or un-grounded equipment). IEC 61000-4-2 defines a Test Generator (ESD simulator), with a discharge resistor (330 Ω) and a discharge capacitor (150 pF). 61000-4-2 strike and, at 8 kV (a common system level ESD requirement), the peak current for an IEC 61000-4-2 strike is over 22 times higher than what most high performance semiconductors are … BS EN 61000-1-2:2016 establishes a methodology for the achievement of functional safety only with regard to electromagnetic phenomena. This methodology includes the implication it has on equipment used in such systems and installations. KSD-D5S002-000 1 SDT05J TVS Diode Features • Transient protection for data lines to IEC 61000-4-2(ESD) 15KV(air), 8KV(contact ) • Small package for use in … IEC 61000-2-1 defines various types of voltage fluctuations. We willrestrict our discussion here to IEC 61000-2-1 Type (d) voltage fluctuations, which are characterized as a series of rndoma or continuous voltage fluctuations. Loads that can exhibit continuous, rapid which meets IEC 61000-4-2 or HMM standard is shown in Fig. 1. Compared with the real waveforms, the results in Fig.6 show that the waveforms of the simulation are consistent with the real waveforms generated by an ESD gun from 2kV to 30kV, and the picture of real waveforms is in Ref [10]. This part of IEC 61000 for EMC emission requirements applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Emission requirements in the frequency range 0 Hz to 400 GHz are covered. No measurement needs to be performed at frequencies where no requirement is specified. BS EN IEC 61000-6-2:2019 for EMC immunity requirements applies to electrical and electronic equipment intended for use in industrial locations, as described below. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. IEC 61000-4-1:2000. Title. Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series . Abstract. Gives applicability assistance to the users and manufacturers of electrical and electronic equipment on EMC standards within the IEC 61000-4 series on testing and measurement techniques. y4 例えば、iec 61000-4-4 や-4-6 でのクランプでの注入に 際しては試験されているケーブルに接続された周辺機器も強い 妨害を受け、iec 61000-4-3 での試験に際してeut の近くに 置かれる周辺機器はeut と同程度の電磁界を受ける。周辺機 IEC 61000-4-4 : Electrically Fast Transients Level 2 – Criteria B IEC 61000-4-5 : Electrical Surges Level 3 – Criteria B E116949 ACCESSORIES DIN Rail Mountable Socket Part no.: DRSED Fingersafe IP10 DIN rail mountable socket to mount ED series relays onto standard 35 mm DIN rail. IEC 61000-4-7 Ed. 2.1 b:2009 Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto CONSOLIDATED EDITION. standard by International Electrotechnical Commission, 10/28/2009 стандарту iec 68-2-27; 100 g. Испытание на падение:1,5 м в соответствии с требованиями стандарта iec 68-2-32. Защита от проникновения пыли/влаги: ip55, в соответствии со стандартом iec 60529. ESD per IEC 61000-4-2 (Air) ESD per IEC 61000-4-2 (Contact) V ESD ±20 ±15 kV Operating Temperature T j-55 to +125 °C Storage Temperature T STG-55 to +150 °C Electrical Characteristics (T = 25°C) Parameter Symbol Condition Min Typ Max Units Reverse Stand-Off Voltage V RWM Between I/O lines to Gnd or I/O to I/O 5 V Reverse Breakdown Voltage ... IECEE Certification & Testing | IEC Standards | IEC 61000-4-2:2008 | Regulatory Requirements IEC 61000-4-x series as well as in the individual product standards. Each standard specifies the conditions for selected interference phenomena, like e.g. IEC 61000-4-2 [1] for ESD, IEC 61000-4-3 [2] for radiated disturbance etc. The test result is affected by various factors and influences. en 61000-4-15 (1998)/a1 (2003) *1 The standard names shown in the table are the codes used by this product. *2 Measurement technology standards referenced by the limit value standards (Both old and new versions are supported.) EN/IEC 61000-4-2 Ed2 & ISO 10605 Ed2 Compliant . SMART ESD simulator which supports all phases of the test (Pre to Post) ESS-S3011A : Product video short version | ESS-S3011A : Product video full version . ESS-S3011A & GT-30RA (Note: Discharge gun stand is an optional accessory.) FEATURES EN/IEC 61000-4-2 Ed2 Compliant peak current of 24 A (8/20 μs current waveform per IEC 61000-4-5). Figure 2 shows the test setup for a differential surge test between the PoE power pairs of a PSE that is supplying power over pins 1, 2, 3 and 6 (referred to as Alternative A in the IEEE 802.3-2012 standard). IEC 61000−4−2 Contact IEC 61000−4−2 Air ISO 10605 330 pF / 330 Contact ISO 10605 330 pF / 2 k Contact ISO 10605 150 pF / 2 k Contact ESD ±25 ±25 ±20 ±30 ±30 kV Stresses exceeding those listed in the Maximum Ratings table may damage the device. If any of these limits are exceeded, device functionality should not be 21 and IEC / EN 61326-3-2. COUPLING DECOUPLING NETWORKS FOR IEC / EN 61000-4-6 0.1 0.15 0.01 1 10 100 230 300 Frequency in MHz Emissions testing, Immunity testing, Extended range * Standard contains additional requirements for the CDN. IEC/EN 61000-4-6: 150 kHz to 80 (230) MHz DNV EN 60335-2-82:2003 + Al :2008 IEC 60335-2-98:2002 (ed.2) + Al :2004 + A2:2008; EN 60335-2-98:2003 + Al :2005 + A2:2008 IEC 60065: 1998 (ed.6); IEC 61000-6-3; emission standard for the residential, commercial and light industrial environment; IEC 61000-6-4; emission standard for the industrial environment; Basic EMC standards. In addition to product specific and generic standards, accreditation is held for many of the basic standards in the IEC/EN 61000-4-X series. IEC 61000-4-15 Ed1.1(2003), EN 61000-4-15(1998)/A1(2003) IEC 61000-3-11 Ed1.0(2000) 16 A or more, 75 A or less *1. ... card in either the PDF or text format. You can easily view and print them using a PC. The text format is useful when you want to prepare a report in Single USB 2.0 ESD protection to IEC 61000-4-2 level 4 8. Package outline Fig 2. Package outline SOT457 (TSOP6) OUTLINE REFERENCES VERSION EUROPEAN PROJECTION ISSUE DATE IEC JEDEC JEITA SOT457 SC-74 bp wBM D e pin 1 index A A1 Lp Q detail X HE E v M A B A y scale c X 132 6 5 4 0 1 2 mm Plastic surface-mounted package (TSOP6); 6 leads SOT457 1 2 2 2 4 4 3 6 8 4 8 16 Better ESD Protection In addition to specifying the stress applied to the device, the IEC 61000-4-2 specification also catego-rizes the results of the ESD strike (ESD Result Classi-fication). The LVCE161284 has been designed to withstand an IEC 61000-4-2 (Level 4) ESD strike and maintain an ESD Result Classification 1 ... Pollution Degree€: 2 in accordance with IEC/EN 61131-2 Max operating Altitude Operation€: 2000 m Transport€: 3,048 m Mechanical resistance Immunity to vibrations IEC/EN 60068-2-6, Fc test Immunity to shock IEC/EN 60068-2-27, Fa test Resistance to electrostatic discharge Immunity to ESD IEC/EN 61000-4-2, level 3 Resistance to HF ... EM CLAMP FOR IEC/ EN 61000-4-6 KEMZ 801A 1000 320 Forward power in W 100 32 10 3.2 1 0.32 0.1 60 55 0.01 0.1 0.15 80 230 1 10 100 1000 Frequency in MHz Frequency range of IEC/EN 61000-4-6, frequency in MHz Forward power in dBm 50 40 45 35 30 25 20 Power requirements in accordance with IEC/ EN 61000-4-6 Partie 2-39: Essais — Essais et lignes directrices: Essais combinés de température ou de température et d'humidité à basse pression atmosphérique IEC 60068-2-39 Edition 2.0 2015-09 INTERNATIONAL ELECTROTECHNICAL COMMISSION COMMISSION ELECTROTECHNIQUE INTERNATIONALE ICS 19.040 ISBN 978-2-8322-2897-5 Warning! IEC 61000-4-6: Level III, 10 Vrms (0,15 to 80 MHz) 80% AM (1 kHz) Immunity to voltage dips and breaks IEC 61000-4-11: Industrial Class II, 0 % residual voltage during 1 cycle AC power ports, 70 % residual voltage during 25/30 cycles AC power ports, 0 % residual voltage, 250/300 cycles AC power ports. Immunity to electrostatic discharges acc. IEC/EN 61000-4-2 Level III (Air 8 K€: contact 6kV) Immunity to radiated, radio-frequency, electromagnetic field acc. IEC/EN 61000-4-3 Level III (10 V/m€: 26 M€Hz to 1 G€Hz / 900 M€Hz) Immunity to rapid transient bursts acc. to IEC/EN 61000-4-4 Level III (Direct 2 … Your search resulted in 60 documents for ""IEC 61000-2-4"" amongst all current documents. Sort By: Most Recent; All; Narrow: Publisher: By Publisher. BS 55 CSA 1 DIN 1 IEC 3 Publication Year: By Year. 2020 2 2019 7 2018 5 2017 4 2016 3 2015 3 ... Electrostatic discharge EN/IEC 61000-4-2 !8kV air, !4kV contact Electromagnetic " eldsEN/IEC 61000-4-310V/m at 0.08 to 1 GHz Electrical fast transient / burst immunity EN/IEC 61000-4-4 Signal: !1kV Surge EN/IEC 61000-4-5Signal: !1kV line-ground Conducted RF EN/IEC 61000-4-610Vrms at 0.15 to 80 MHz EN60950-1: Meets the requirements of sections1.5: 1,7: 2.9: 2.10.5.3: 4.2: 4.5: 4.7: IEC 61000-4-2 Electrostatic Discharge Level 3 IEC 61000-4-4 Electrically Fast Transients Level 3 IEC 61000-4-5 Electrical Surges Level 3 www.crydom.com Panel Mount IEC 61000−4−2 Spec. Level Test Volt-age (kV) First Peak Current (A) Current at 30 ns (A) Current at 60 ns (A) 1 2 7.5 4 2 2 4 15 8 4 3 6 22.5 12 6 4 8 30 16 8 Ipeak 90% 10% IEC61000−4−2 Waveform 100% I @ 30 ns I @ 60 ns tP = 0.7 ns to 1 ns Figure 3. IEC61000−4−2 Spec Figure 4. Diagram of ESD Test Setup 50 Cable Device Under Test ESD ... IPP 4 . A . 8/20µs, Figure 3 . ESD Protection – Contact Discharge . VESD_Contact ±30 . kV . IEC 61000-4-2 Standard . ESD Protection – Air Discharge . VESD_Air ±30 . kV . IEC 61000-4-2 Standard . Device Schematic Top View SOD923 TM M = Product Type Marking Code Pin 2 Pin 1 D12V0M1U2S9 Document number: DS37088 Rev. 1 - 2 1 August 2014of 5 EN 61000-3-3:2008, IEC 61000-4-2:2008, IEC 61000-4-3:2010, IEC 61000-4-4:2012, IEC 61000-4-5:2005, IEC 61000-4-6:2008, IEC 61000-4-8:2009, IEC 61000-4-11:2004 Electrical Power 12 VDC or PoE (802.3af) Requires a separate 12 VDC power supply, or power via a PoE switch. Power Consumption IEC/EN 61000-4-2, level 3 Resistance to HF interference Immunity to radiated electrostatic fields IEC/EN 61000-4-3 Immunity to fast transients (burst immunity) IEC/EN 61000-4-4, level 3 Immunity to shock waves IEC/EN 61000-4-5 Radio frequency in common mode